{"title":"Data Acquisitions","description":"","products":[{"product_id":"keysight-daq970a","title":"Keysight \/ Agilent DAQ970A Data Acquisition\/Switch Unit, USB, LAN","description":"\u003cp\u003e\u003cstrong\u003eKeysight \/ Agilent DAQ970A Data Acquisition\/Switch Unit, USB, LAN, GPIB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe DAQ970A data acquisition system has high-quality switching and an advanced 6-½ digit DMM built-in that allows you to measure accurately.\u003c\/p\u003e\n\u003cp\u003eThe autocalibration compensates for drifts in the internal DMM or on the DAQM907A multifunction module or on the DAQM909A digitizer module caused by time and temperature change.\u003c\/p\u003e\n\u003cp\u003eBuilt-in internal module calibration reduces thermal voltage offset errors.\u003c\/p\u003e\n\u003cp\u003eAbility to measure very low current ranges (1 µA DC and 100 µA AC) and higher resistance range (1000 MΩ).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-slot mainframe with built-in 6-½ digit DMM\u003c\/li\u003e\n\u003cli\u003eBasic 0.003% DCV accuracy\u003c\/li\u003e\n\u003cli\u003e9 switch, RF, and control plug-in modules, including a new 4-channel simultaneous sampling digitizer\u003c\/li\u003e\n\u003cli\u003eUp to 450 channel\/s scan rate\u003c\/li\u003e\n\u003cli\u003eUp to 120 channels per system\u003c\/li\u003e\n\u003cli\u003eUp to one million points scanning memory\u003c\/li\u003e\n\u003cli\u003eMeasures and converts 14 different input signals: Temperature with thermocouple, RTDs, and thermistor; dc\/ac volts; 2- and 4-wire resistance; frequency and period; dc\/ac current, diode and capacitance; direct strain and bridge strain\u003c\/li\u003e\n\u003cli\u003eLarge 4.3\" color display for ease of setup and viewing data\u003c\/li\u003e\n\u003cli\u003eCode compatible with the 34970A\/34972A\u003c\/li\u003e\n\u003cli\u003eUSB flash drive support to copy\/log data in standalone applications\u003c\/li\u003e\n\u003cli\u003eBenchVue DAQ with enhanced time\/frequency domain measurement included\u003c\/li\u003e\n\u003cli\u003eLAN \u0026amp; USB interfaces\u003c\/li\u003e\n\u003cli\u003e100 - 240 Vac ±10%; 50\/60\/400 Hz operation\u003c\/li\u003e\n\u003cli\u003eWeight: 4.2 kg; Size: 103.7 mm H x 261 mm W x 378 mm D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePlease see Datasheet for complete details and specifications.\u003c\/p\u003e","brand":"Keysight \/ Agilent","offers":[{"title":"Agilent DAQ970A Data Acquisition\/Switch Unit with DMM and 1 each DAQM900A","offer_id":52537725157719,"sku":"KTADAQ970A-DAQM900A","price":1.0,"currency_code":"USD","in_stock":true},{"title":"Agilent DAQ970A Data Acquisition\/Switch Unit with DMM and 1 each DAQM901A","offer_id":52537725190487,"sku":"KTADAQ970A-1-DAQM901A","price":1.0,"currency_code":"USD","in_stock":true},{"title":"Agilent DAQ970A Data Acquisition\/Switch Unit with DMM","offer_id":52537725223255,"sku":"KTADAQ970A","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/9389\/0135\/files\/KTADAQ970A.jpg?v=1768380492"},{"product_id":"fluke-2620a","title":"New Fluke 2620A Hydra Series II Data Acquisition Unit, 21 Channel Analog Input","description":"\u003cp\u003e\u003cstrong\u003eFluke 2620A Hydra Series II Data Acquisition Unit, 21 Channel Analog Input\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2620A Hydra Series II Data Acquisition Unit is a multi-channel data acquisition unit able to measure ac and dc voltages, temperature via thermocouples and RTDs, resistance, and frequency. It features 21 measurement channels, 8 digital input\/output lines, a Totalizer input, and 4 alarm output lines. The Data Acquisition Unit is easily carried by hand and can be ac or dc powered. The user can choose communications with a host computer over an RS-232 (standard) or IEEE-488 (2620A\/05) computer interface.\u003c\/p\u003e\n\u003cp\u003eThe 2620A comes with a removable Universal Input Module that enables fast, convenient set-up and reconfiguration. Any combination of dc voltage, ac voltage, thermocouple, RTD, resistance, or frequency measurements can be connected to the input module without the need for additional signal conditioning. Thermocouple reference junction compensation is automatically performed by sensing the temperature of the input module's isothermal block.\u003c\/p\u003e\n\u003cp\u003eThe Hydra 2620A is ideal for applications that require direct connection to a PC for real-time data collection.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eEasy-to-use front-end.\u003c\/b\u003e An RS-232 serial interface makes it easy to connect the Hydra Data Acquisition Unit to a PC or modem for real-time data acquisition. The 2620A can also be used as a 20-channel panel meter.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIEEE interface.\u003c\/b\u003e An \u003cu\u003eoptional\u003c\/u\u003e IEEE-488 interface allows you to easily integrate the 2620A with other IEEE-488 instruments and your PC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChannel Scanning: can be continuous scanning, scanning at an interval time, single scans, or triggered (internal or external) scans\u003c\/li\u003e\n\u003cli\u003eChannel Monitoring: make measurements on a single channel and view these measurements on the display\u003c\/li\u003e\n\u003cli\u003eChannel Scanning and Monitoring: view measurements made for the monitor channel while scanning of all active channels continues\u003c\/li\u003e\n\u003cli\u003eMulti-Function Display: Left (numeric) display shows measurement readings; also used when setting numeric parameters; Right (alphanumeric) display used for numeric entries, channel number selection and display, status information, and operator prompts\u003c\/li\u003e\n\u003cli\u003eFront-Panel Operation\u003c\/li\u003e\n\u003cli\u003eMeasurement Input Function and Range:\u003cbr\u003e  Volts dc (Vdc), dc voltage ranges 300 mV, 3 V, 30 V, 300 V\u003cbr\u003e  Volts ac (Vac), ac voltage ranges 300 mV, 3 V, 30 V, 300 V\u003cbr\u003e  Frequency (Hz), 15 Hz to 1 MHz\u003cbr\u003e  Resistance (Ω), resistance ranges: 300Ω, 3 kΩ, 30 kΩ, 300 kΩ, 3 MΩ, 10 MΩ\u003c\/li\u003e\n\u003cli\u003eTemperature Measurement: Thermocouple types J, K, E, T, N, R, S, and B, and Hoskins Engineering Co. type C are supported. Also, DIN\/IEC 751 Platinum RTDs are supported\u003c\/li\u003e\n\u003cli\u003eTotalize Events on the Totalizing Input\u003c\/li\u003e\n\u003cli\u003eAlarm Limits and Digital Output Alarm Indication\u003c\/li\u003e\n\u003cli\u003e4-Terminal Resistance Measurements (Channels 1 through 10 only)\u003c\/li\u003e\n\u003cli\u003eRS-232 Computer Interface Operation\u003c\/li\u003e\n\u003cli\u003eMeasurement Rate Selection\u003c\/li\u003e\n\u003cli\u003eNonvolatile Memory: Storage of minimum, maximum, and most recent measurements for all scanned channels. Storage of Computer Interface setup, channel configurations, and calibration values.\u003c\/li\u003e\n\u003cli\u003eRS-232 interface (IEEE-488 available when ordering option 05)\u003c\/li\u003e\n\u003cli\u003e90 to 264 Vac, 50 or 60 Hz operation; or 9.0 to 16 Vdc\u003c\/li\u003e\n\u003cli\u003eWeight: 7 lb; Size: 93 mm (3.67 in)H x 216 mm (8.5 in)W x 312 mm (12.3 in)D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePlease see Datasheet for complete details and specifications.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":52537745211735,"sku":"FLKR2620A-05","price":1595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/9389\/0135\/files\/2620A_3.jpg?v=1768380755"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/9389\/0135\/collections\/Data_Acquisition.jpg?v=1772608972","url":"https:\/\/www.tsdwelltest.com\/collections\/data-acquisitions\/data-acquisition.oembed","provider":"TSD Welltest Solution","version":"1.0","type":"link"}